Click for Print View   Click to Open Literature Page
HAMX-50, Click to Close
Click for Print View   Click to Open Literature Page
GHAMX-150, Click to Close
Click for Print View   Click to Open Literature Page
HPFR-HAMX-3000, Click to Close
Click for Print View   Click to Open Literature Page
HPFR-HAMX-3000-H150-H300, Click to Close
Click for Print View
Internal Flux Cone, Click to Close
Click On
Earth to See
Resources
Saved!!
Click On
Earth to See
Resources
Saved!!
Click on Earth for Money Saver Calculator
Weld Engineering Header
"MANUFACTURERS OF THE MOST COMPLETE LINE OF SUBMERGED ARC FLUX HANDLING EQUIPMENT IN THE WORLD"
ENGINEERING CO., INC.
Excellence Since 1979
Flux Recovery, Earth Resource Recovery, Save Flux, Save the Earth, Save Money
34 FRUIT ST.
SHREWSBURY, MA 01545 U.S.A.
PHONE: (508) 842-2224
FAX: (508) 842-3893
Checkmark

HAMX-50, Click on for a larger image GHAMX-150, Click on for a larger image HPFR-HAMX-3000, Click on for a larger image HPFR-HAMX-3000-H150/H300, Click on for a larger image
HAMX-50 GHAMX-150
  • The HAMX-50 is a heated (control up to 250°F {121°C}) flux hopper/separator.
  • Top hopper has two 50 pound capacity sections, one for recovered flux and one for new flux.
  • Flux from both sections mix together at a preset ratio as the flux is transferred into the the pressure tank.
  • Each section features a high and low level sight window.
  • The HAMX-50 is very useful for sub-arc welding when code requires a specific percentage of new flux to be mixed with recovered flux.
  • Optional MAGSEP-2 separates out magnetic particles from recovered flux.
  • Optional Electronic Flux Level Sensor. A high or low flux level sensor is available to sense flux level of hopper. A loud audible alarm and flashing red light on control panel will signal operator.
  • Complete System Options

    Open Literature Page (PDF)

  • The GHAMX-150 is a heated (control up to 250°F {121°C}) flux hopper/separator.
  • Top hopper has two 150 pound capacity sections, one for recovered flux and one for new flux.
  • Flux from both sections mix together at a preset ratio as the flux is transferred into the the pressure tank.
  • Each section features a high and low level sight window.
  • The GHAMX-150 is very useful for sub-arc welding when code requires a specific percentage of new flux to be mixed with recovered flux.
  • Optional MAGSEP-100 separates out magnetic particles from recovered flux.
  • Optional Electronic Flux Level Sensor. A high or low flux level sensor is available to sense flux level of hopper. A loud audible alarm and flashing red light on control panel will signal operator.
  • Complete System Options

    Open Literature Page (PDF)

HPFR-HAMX-3000
  • The HPFR-HAMX-3000 is a heated (control up to 250°F {121°C}) flux hopper/separator and pressure feed system.
  • Top hopper has two 50 pound capacity sections, one for recovered flux and one for new flux.
  • Flux from both sections mix together at a preset ratio as the flux is transferred into the the pressure tank.
  • Each section features a high and low level sight window.
  • The HPFRHAMX-3000 is very useful for sub-arc welding when code requires a specific percentage of new flux to be mixed with recovered flux.
  • Optional MAGSEP-2 separates out magnetic particles from recovered flux.
  • Optional Electronic Flux Level Sensor. A high or low flux level sensor is available to sense flux level of pressure tank or hopper. A loud audible alarm and flashing red light on control panel will signal operator.
  • Heated 100 LB. pressure feed tank. Larger tanks are available.
  • Manufactured with an internal flux cone. This allows complete draining of all flux out of tank. There is no stagnant area in the tank from which flux will not flow out of tank.

    Tank Options

    Complete System Options

    Open Literature Page (PDF)

HPFR-HAMX-3000-H150/H300
  • The HPFR-HAMX-3000-H150/H300 is a heated (control up to 250°F {121°C}) flux hopper/separator and pressure feed system.
  • Top hopper has two 150 pound capacity sections, one for recovered flux and one for new flux.
  • Flux from both sections mix together at a preset ratio as the flux is transferred into the the pressure tank.
  • Each section features a high and low level sight window.
  • The HPFRHAMX-3000-H150/H300 is very useful for sub-arc welding when code requires a specific percentage of new flux to be mixed with recovered flux.
  • Optional MAGSEP-100 separates out magnetic particles from recovered flux.
  • Optional Electronic Flux Level Sensor. A high or low flux level sensor is available to sense flux level of pressure tank or hopper. A loud audible alarm and flashing red light on control panel will signal operator.
  • Heated 300 LB. pressure feed tank. Larger tanks are available.
  • Manufactured with an internal flux cone. This allows complete draining of all flux out of tank. There is no stagnant area in the tank from which flux will not flow out of tank.

    Tank Options